INTERNATIONAL CONFIGURATIONS, INC.
International Wiring Accessories and Cord Sets
Find Part Number:
Find Catalog Page:
Telephone: 860-749-6380
Fax: 860-749-2985
E-mail: sales@internationalconfig.com

European/International GFCI (RCBO/RCD Surface Mount Outlets, IP55/IP20)

Select from the following product types for: GFCI (RCBO/RCD Surface Mount Outlets,IP55/IP20)
4721-10HG2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-10HG3

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R, 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-10HH2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA. TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS (**), GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-10VG2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-10VH2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS (**). GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-30HG2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-30HG3

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R, 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-30HH2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS (**), GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-30VG2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60Hz, (30mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm. Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4721-30VH2

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS (**). GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4722-10HG2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-10HG3

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT DUPLEX OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-10HH2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-10VG2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-10VH2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-30HG2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-30HG3

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT DUPLEX OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-30HH2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-30VG2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, GLAND CABLE ENTRY, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4722-30VH2

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), VERTICAL SURFACE MOUNT, IP20 RATED, M20 CABLE ENTRY HUBS, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

4731-10HG2

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP20 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

4731-10HG3

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) DUPLEX OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.

4731-30HG2

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" Designs and IP66 rated versions available. GFCI (RCBO/RCD) Outlets are available for all countries.

4731-30HG3

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) DUPLEX OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.

4821-10HP

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA. TRIP), PANEL MOUNT OR FLUSH BOX MOUNT. GRAY.
Notes:
* Mating flush mount wall box #77190-D.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66, IP55 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

4821-10HPD

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) (EU1-16R) DUPLEX OUTLET, TYPE F, 50/60 Hz, (10mA TRIP), PANEL MOUNT OR FLUSH WALL BOX MOUNT. GRAY.
Notes:
* Mating flush mount wall box #77190-D3.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof surface mount IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

5021-10HP

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA.TRIP), WEATHERPROOF IP55 RATED, PANEL MOUNT OR FLUSH WALL BOX MOUNT. GRAY.
Notes:
* Mating flush mount wall box #77190-D.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof surface mount IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

5021-10HPD

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), WEATHERPROOF IP55 RATED, PANEL MOUNT OR FLUSH WALL BOX MOUNT, (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Mating flush mount wall box #77190-D3.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof surface mount IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

5021-30HP

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), WEATHERPROOF IP55 RATED, PANEL MOUNT OR FLUSH WALL BOX MOUNT. GRAY.
Notes:
* Mating flush mount wall box #77190-D.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof surface mount IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

5023-10HP

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI (RCBO/RCD) OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, ( 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL PANEL MOUNT, WALL BOX MOUNT, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

5023-30HP

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI (RCBO/RCD) OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, ( 30mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL PANEL MOUNT, WALL BOX MOUNT, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

63225

INDIA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, IS 1293:2005, TYPE M IN1-16R), 6 AMPERE-250 VOLT OUTLET, TYPE D (IN2-6R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* ISI mark, BIS approved outlet.
* Accepts India 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

63225-30

INDIA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, IS 1293:2005, TYPE M IN1-16R), 6 AMPERE-250 VOLT OUTLET, TYPE D (IN2-6R), 50/60 Hz, 30mA TRIP, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* ISI mark, BIS approved outlet.
* Accepts India 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

63225-30D

INDIA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) DUPLEX OUTLET, IS 1293:2005, TYPE M IN1-16R), 6 AMPERE-250 VOLT OUTLET, TYPE D (IN2-6R), 50/60 Hz, 30mA TRIP, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* ISI mark, BIS approved outlet.
* Accepts India 16A-250V type M, 6A-250V type D plugs.
* GFCI (RCBO/RCD) outlets are available for all countries.

70225

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10-IT

EUROPEAN SCHUKO, ITALY, CHILE, SOUTH AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, CEE 7/3 TYPE E, F, (EU1-16R), TYPE L, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts Type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs & Italy, Chile type L 10 Ampere & 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10HG

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) (EU1-16R) OUTLET, 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10HGD

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10HH

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), IP55 RATE WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**), HORIZONTAL SURFACE MOUNT, 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10VG

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY), VERTICAL SURFACE MOUNT. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10VH

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**), VERTICAL SURFACE MOUNT. GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30

EUROPEAN SCHUKO 16A-250V CEE 7/3 GFCI (RCBO/RCD) (EU1-16R) OUTLET, 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY), 2 POLE-3 WIRE GROUNDING (2P+E). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30-IT

EUROPEAN SCHUKO, ITALY, CHILE, SOUTH AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, CEE 7/3 TYPE E, F, (EU1-16R), TYPE L, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (30mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts Type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs & Italy, Chile type L 10 Ampere & 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30D

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30HG

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) (EU1-16R) OUTLET, 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30HGD

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30HH

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30VG

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) (OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY), VERTICAL SURFACE MOUNT. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30VH

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) OUTLET, TYPE F (EU1-16R), 50/60 Hz, (30mA TRIP), IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**), VERTICAL SURFACE MOUNT. GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-D

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

71225

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm. Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

71225-10HGD

FRANCE, BELGIUM GFCI (RCBO/RCD) 16A-230V DUPLEX OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.

71225-10HH

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

71225-10VG

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), VERTICAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY) GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

71225-10VH

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), VERTICAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

71225-30

FRANCE, BELGIUM GFCI GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm. Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

71225-30HGD

FRANCE, BELGIUM GFCI (RCBO/RCD) 16A-230V DUPLEX OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.

71225-30HH

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

71225-30VG

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), VERTICAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY) GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.

71225-30VH

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), VERTICAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm.
* Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

72325

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, GLAND TYPE CABLE ENTRY, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

72325-10HH

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, (**) M20 HUB TYPE CABLE ENTRIES, CLEAR LIFT LID COVERS. GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

72325-10VH

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, VERTICAL SURFACE MOUNT WALL BOX, (**) M20 HUB TYPE CABLE ENTRIES, CLEAR LIFT LID COVERS. GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

72325-30

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 30mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, GLAND TYPE CABLE ENTRY, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

72325-30D

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD DUPLEX OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 30mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, GLAND TYPE CABLE ENTRY, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

72325-30HH

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 30mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, (**) M20 HUB TYPE CABLE ENTRIES, CLEAR LIFT LID COVERS. GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

72325-30VH

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, ( 30mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, VERTICAL SURFACE MOUNT WALL BOX, (**) M20 HUB TYPE CABLE ENTRIES, CLEAR LIFT LID COVERS. GRAY.
Notes:
** M20 adapter #01614 available. Converts M20 to 1/2 inch National Pipe Thread (NPT).
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

72325-D

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD DUPLEX OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, GLAND TYPE CABLE ENTRY, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

73225

SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 / TYPE M (UK1-15R), 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E), IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY **), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts South Africa 25A-250V, 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

73225-30

SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 / TYPE M (UK1-15R), 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R), 50/60 Hz, 30mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E), IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY **), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts South Africa 25A-250V, 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

73225-30D

SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) DUPLEX OUTLET, BS 546 / TYPE M (UK1-15R), 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R), 50/60 Hz, 30mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E), IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY **), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts South Africa 25A-250V, 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

74325-10HG

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI [RCBO/RCD] OUTLET, 13A-230V, 50/60 Hz, [10mA TRIP], TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY [**], HORIZONTAL SURFACE MOUNT, GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO [single pole + neutral] provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

74325-10HGD

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD)DUPLEX OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 250 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.

74325-30HG

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

74325-30HGD

UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD)DUPLEX OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 250 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.

74335-10

AUSTRALIAN / NEW ZEALAND 10A-230V GFCI (RCBO/RCD) OUTLET (AU1-10R), 50/60 Hz, (10mA TRIP), IP55, SURFACE MOUNT. GRAY.

74335-30

AUSTRALIAN / NEW ZEALAND 10A-230V GFCI (RCBO/RCD) OUTLET (AU1-10R), 50/60 Hz, (30mA TRIP), IP55, SURFACE MOUNT. GRAY.

74725

CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Protects Downstream outlets.
* No reset after power failure (Latched RCD).
* Outlet accepts 10 ampere (CH1-10P) China plugs only.

74725-10HH

CHINA 10A-250V GFCI (RCBO/RCD) OUTLET, TYPE I (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (*), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Outlet accepts 10 ampere (CH1-10P) China plugs only.

74725-30

CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 30mA TRIP, IP55, HORIZONTAL MOUNT. GRAY.
Notes:
* Outlet accepts 10 ampere (CH1-10P) China plugs only.

74726

CHINA 16A-230V GFCI (RCBO / RCD) GFCI POWER OUTLET (CH2-16R), 50/60 Hz, 10mA TRIP, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Outlet accepts 16 ampere (CH2-16P) China plugs only.

74726-30

CHINA 16A-230V GFCI (RCBO / RCD) GFCI POWER OUTLET (CH2-16R), 50/60 Hz, 30mA TRIP, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Outlet accepts 16 ampere (CH2-16P) China plugs only.

75525

ITALY, CHILE, SOUTH AMERICA 10A/16A-230V GFCI (RCBO/RCD) TYPE L DUPLEX OUTLET, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED ENCLOSURE, HORIZONTAL SURFACE MOUNT, GLAND TYPE CABLE ENTRY (**). GRAY.
Notes:
* Accepts Italy, Chile Type L 10 Ampere, 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets available.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

75525-30

ITALY, CHILE, SOUTH AMERICA 10A/16A-230V GFCI (RCBO/RCD) TYPE L DUPLEX OUTLET, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (30mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED ENCLOSURE, HORIZONTAL SURFACE MOUNT, GLAND TYPE CABLE ENTRY (**). GRAY.
Notes:
* Accepts Type Italy, Chile type L 10 Ampere, 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets available.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

76225

SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

76225-30

SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 H, 30mA TRIP, IP55 RATED. HORIZONTAL SURFACE MOUNT. GRAY.

76226

SWITZERLAND 16A-230V T23 SEV 1011 (SW2-16R & SW1-10R) 50/60 Hz GFCI (RCBO/RCD) OUTLET, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

76226-30

SWITZERLAND 16A-230V T23 SEV 1011 (SW2-16R & SW1-10R) 50/60 Hz GFCI (RCBO/RCD) OUTLET, 30mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

77225

ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 10mA TRIP, 50/60 Hz, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

77225-30

ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 30mA TRIP, 50/60 Hz, IP55 RATED. GRAY.

78225

DENMARK, DANISH 13A-230V GFCI (RCBO/RCD) TYPE K OUTLET, (DE1-13R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

78225-30

DENMARK 13A-250V GFCI (RCBO/RCD) OUTLET, AFSNIT 107-2-D (DE1-13R), 50/60 Hz, 30mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

84225-10HG

ARGENTINA 10A-230V GFCI (RCBO/RCD) OUTLET (AR1-10R), 50/60 Hz, (10mA TRIP), IP55 RATED, SURFACE MOUNT. GRAY.

84225-30HG

ARGENTINA 10A-230V GFCI (RCBO/RCD) OUTLET (AR1-10R), 50/60 Hz, (30mA TRIP), IP55 RATED, SURFACE MOUNT. GRAY.

85225

BRAZIL 10A-230V GFCI (RCBO/RCD) OUTLET, NBR 14136 TYPE N (BR2-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
NOTES:
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.

85225-30

BRAZIL 10 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, NBR 14136 TYPE N (BR2-10R), 50/60 Hz 30mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
NOTES:
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.

85226

BRAZIL 16A-230V GFCI (RCBO/RCD) OUTLET, NBR 14136 TYPE N (BR3-20R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Outlet accepts Type N Brazil 20A-250V, 10A-250V, 2.5A-250V & South Africa 16A-250V Type N Plugs, Power Cords.

85226-30

BRAZIL 16A-250V GFCI (RCBO/RCD) OUTLET, NBR 14136 TYPE N (BR3-20R), 50/60 Hz 30mA TRIP, IP55 RATED. HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Outlet accepts Type N Brazil 20A-250V, 10A-250V, 2.5A-250V & South Africa 16A-250V Type N Plugs, Power Cords.