NEMA Locking Wiring Devices and Cord Sets
Select from the following product types for: 'Flanged Inlets, NEMA Locking'
4716-SS
15A-125V NEMA L5-15P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5200-WC cover & #5200-WTC terminal shield or # 79480 WP Cover.
* Temp. range = -40°C to +75°C. Terminals accept 16AWG-10AWG. Max. torque = 11 in. lbs.
** NEMA Panel Mount Power Inlets with same mounting pattern listed below.
**NEMA L5-15R LOCKING inlet #4716-SS (15A-125V). Accepts NEMA L5-15R Locking connectors.
**NEMA L6-15P LOCKING inlet #L615-FI (15A-250V). Accepts NEMA L6-15R Locking connectors.
**NEMA 5-15P Inlet #5278-SS (15A-125V). Accepts NEMA 5-15R & NEMA 5-20R connectors.
**NEMA 5-20P Inlet #5378-SS (20A-125V). Accepts NEMA 5-20R connectors.
**NEMA 6-15P Inlet #5678-SS (15A-250V). Accepts NEMA 6-15R connectors & NEMA 6-20R connectors.
**NEMA 6-20P Inlet #5478-SS (20A-250V). Accepts NEMA 6-20R connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Inlets & Outlets Guide
L1420-FI
20A-125/250V NEMA L14-20P FLANGED PANEL MOUNT POWER INLET, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1420-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1430-FI
30A-125/250V NEMA L14-30P FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1430-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1520-FI
20 AMPERE-250 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L15-20P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1520-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1530-FI
30 AMPERE-250 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L15-30P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1530-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1620-FI
20 AMPERE-480 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L16-20P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1620-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1630-FI
30 AMPERE-480 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L16-30P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1630-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L2120-FI
20A-120/208V AC, 3 PHASE Y, NEMA L21-20P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L2130-FI
30A-120/208V AC, 3 PHASE Y, NEMA L21-30P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L2220-FI
20A-277/480V AC, 3 PHASE Y, NEMA L22-20P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L2230-FI
30A-277/480V AC, 3 PHASE Y, NEMA L22-30P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L520-FI
20A-125V NEMA L5-20P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Outlets & Inlets Guide
L530-FI
30A-125V NEMA L5-30P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power inlets. NEMA Flanged Outlets & Inlets Guide
L615-FI
15A-250V NEMA L6-15P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5200-WC cover & #5200-WTC terminal shield or # 79480 WP Cover.
* Temp. range = -40°C to +75°C. Terminals accept 16AWG-10AWG. Max. torque = 11 in. lbs.
** NEMA Panel Mount Power Inlets with same mounting pattern listed below.
**NEMA 5-15P Inlet #5278-SS (15A-125V). Accepts NEMA 5-15R & NEMA 5-20R connectors.
**NEMA 5-20P Inlet #5378-SS (20A-125V). Accepts NEMA 5-20R connectors.
**NEMA 6-15P Inlet #5678-SS (15A-250V). Accepts NEMA 6-15R connectors & NEMA 6-20R connectors.
**NEMA 6-20P Inlet #5478-SS (20A-250V). Accepts NEMA 6-20R connectors.
**NEMA L5-15R LOCKING inlet #4716-SS (15A-125V). Accepts NEMA L5-15R Locking connectors.
**NEMA L6-15P LOCKING inlet #L615-FI (15A-250V). Accepts NEMA L6-15R Locking connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Inlets & Outlets Guide
L620-FI
20A-250V NEMA L6-20P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Outlets & Inlets Guide
L630-FI
30A-250V NEMA L6-30P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Outlets & Inlets Guide
15A-125V NEMA L5-15P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5200-WC cover & #5200-WTC terminal shield or # 79480 WP Cover.
* Temp. range = -40°C to +75°C. Terminals accept 16AWG-10AWG. Max. torque = 11 in. lbs.
** NEMA Panel Mount Power Inlets with same mounting pattern listed below.
**NEMA L5-15R LOCKING inlet #4716-SS (15A-125V). Accepts NEMA L5-15R Locking connectors.
**NEMA L6-15P LOCKING inlet #L615-FI (15A-250V). Accepts NEMA L6-15R Locking connectors.
**NEMA 5-15P Inlet #5278-SS (15A-125V). Accepts NEMA 5-15R & NEMA 5-20R connectors.
**NEMA 5-20P Inlet #5378-SS (20A-125V). Accepts NEMA 5-20R connectors.
**NEMA 6-15P Inlet #5678-SS (15A-250V). Accepts NEMA 6-15R connectors & NEMA 6-20R connectors.
**NEMA 6-20P Inlet #5478-SS (20A-250V). Accepts NEMA 6-20R connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Inlets & Outlets Guide
L1420-FI
20A-125/250V NEMA L14-20P FLANGED PANEL MOUNT POWER INLET, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1420-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1430-FI
30A-125/250V NEMA L14-30P FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1430-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1520-FI
20 AMPERE-250 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L15-20P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1520-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1530-FI
30 AMPERE-250 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L15-30P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1530-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1620-FI
20 AMPERE-480 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L16-20P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1620-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L1630-FI
30 AMPERE-480 VOLT, 3 PHASE (X,Y,Z,+G) NEMA L16-30P LOCKING FLANGED PANEL MOUNT POWER INLET. WHITE.
Notes:
* Weatherproof / dust proof applications use #5202-WC cover or #79485 cover.
View: Mating power connector # L1630-C.
View: High Power NEMA Locking 20A- 30A (4Pole / 5 Pole) Inlets & Outlets. NEMA Flanged Outlets & Inlets Guide
L2120-FI
20A-120/208V AC, 3 PHASE Y, NEMA L21-20P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L2130-FI
30A-120/208V AC, 3 PHASE Y, NEMA L21-30P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L2220-FI
20A-277/480V AC, 3 PHASE Y, NEMA L22-20P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L2230-FI
30A-277/480V AC, 3 PHASE Y, NEMA L22-30P LOCKING FLANGED INLET, IMPACT RESISTANT NYLON BODY. WHITE.
Notes:
* For weatherproof / dustproof panel mount applications use #5202-WC inlet cover.
L520-FI
20A-125V NEMA L5-20P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Outlets & Inlets Guide
L530-FI
30A-125V NEMA L5-30P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power inlets. NEMA Flanged Outlets & Inlets Guide
L615-FI
15A-250V NEMA L6-15P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON, SPECIFICATION GRADE. WHITE.
Notes:
* Weatherproof / dust proof applications use #5200-WC cover & #5200-WTC terminal shield or # 79480 WP Cover.
* Temp. range = -40°C to +75°C. Terminals accept 16AWG-10AWG. Max. torque = 11 in. lbs.
** NEMA Panel Mount Power Inlets with same mounting pattern listed below.
**NEMA 5-15P Inlet #5278-SS (15A-125V). Accepts NEMA 5-15R & NEMA 5-20R connectors.
**NEMA 5-20P Inlet #5378-SS (20A-125V). Accepts NEMA 5-20R connectors.
**NEMA 6-15P Inlet #5678-SS (15A-250V). Accepts NEMA 6-15R connectors & NEMA 6-20R connectors.
**NEMA 6-20P Inlet #5478-SS (20A-250V). Accepts NEMA 6-20R connectors.
**NEMA L5-15R LOCKING inlet #4716-SS (15A-125V). Accepts NEMA L5-15R Locking connectors.
**NEMA L6-15P LOCKING inlet #L615-FI (15A-250V). Accepts NEMA L6-15R Locking connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Inlets & Outlets Guide
L620-FI
20A-250V NEMA L6-20P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Outlets & Inlets Guide
L630-FI
30A-250V NEMA L6-30P LOCKING FLANGED PANEL MOUNT POWER INLET, IMPACT RESISTANT NYLON BODY, SPECIFICATION GRADE. WHITE.
Notes:
* For weatherproof / dust proof applications use #5201-WC cover or #79485 cover.
* NEMA Panel Mount Power Inlets with same mounting design listed below.
**NEMA #L5-20FI Locking Inlet(20A-125V). Accepts Nema L5-20C Connectors.
**NEMA #L5-30FI Locking Inlet(30A-125V). Accepts Nema L5-30C Connectors.
**NEMA #L6-20FI Locking Inlet(20A-250V). Accepts Nema L6-20C Connectors.
**NEMA #L6-30FI Locking Inlet(30A-250V). Accepts Nema L6-30C Connectors.
View: High Power NEMA Locking 20A, 30A Power Inlets. NEMA Flanged Outlets & Inlets Guide