Part Number | 70400-10MA |
Description: | INTERNATIONAL-LINE GFCI (RCCB / RCD) PRCD-S 16 AMPERE-230/240 VOLT, 50Hz, 10mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, 2 POLE-3 WIRE GROUNDING (2P+E). TEST / RESET BUTTONS. BLACK. RoHS COMPLIANT, TUV, CE.
Notes: * Operating temp. = -25°C to +40°C. * Requires “Reset” after power failure. Not for use on freezers, refrigerators, life support equipment or equipment where power must be maintained. * GFCI (RCD) outlets, sockets, receptacles, In-line connectors, extension cords listed below in related products. Scroll down to view. |
Approvals: | TUV, CE |
Certifications: | REACH, RoHS, CE, WEEE |
Technical Data: | View Technical Data Drawing: 70400-10MA.pdf |
Price & Avail: | Contact Sales Office for Price and Delivery: Quantity Discount Incentives Available - Majority of all Products are in Stock |
Scroll down to view
Related Products
Related Products
Related Products:
70400-10MA
INTERNATIONAL IN-LINE GFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 10mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
70400-30MA
INTERNATIONAL IN-LINEGFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 30mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
83100
UK, BRITISH, UNITED KINGDOM, SAUDI ARABIA, GULF STATES, 13A-250V POWER SUPPLY CORD, BS 1363A TYPE G, UK1-13P, UK, BRITISH UNITED KINGDOM PLUG, 13 AMP. BS 1362 FUSE, STRIPPED ENDS, 2.5 METERS [8FT-2IN] [98"] LONG. BLACK.
Length: 2.5 METERS [8FT-2IN]
82070
AUSTRALIA / NEW ZEALAND 15 AMPERE-250 VOLT POWER SUPPLY CORD, AS/NZS 4417 [RCM] / AS/NZS 3112 PLUG, TYPE I [AU2-15P], GTSA-3 1.5mm2 CORD, 2 POLE-3 WIRE GROUNDING [2P+E], STRIPPED ENDS, 2.5 METERS [8FT-2IN] [98"] LONG. BLACK.
Length: 2.5 METERS [8FT-2IN]
81070
EUROPEAN CEE 7/7 SCHUKO 16A-250V POWER SUPPLY CORD, [EU1-16P] TYPE E, F PLUG, STRIPPED ENDS, 2.5 METERS [8FT-2IN] [98"] LONG. BLACK.
Length: 2.5 METERS [8FT-2IN]
36025-RCDS10
EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 (EU1-16P) TYPE E PLUG WITH IN-LINE GFCI /RCD, 10mA TRIP, TEST/RESET BUTTON, SCHUKO CEE 7/3 (EU1-16R) TYPE F CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* GFCI / RCD 10MA Trip Inline length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 30MA Trip Versions .
* GFCI / RCD Plug Versions: 36025-RCD , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .
36025-RCDS30
EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 TYPE E (EU1-16P) PLUG WITH "IN-LINE" GFCI /RCD, 30mA TRIP, TEST/RESET BUTTON, SCHUKO CEE 7/3 TYPE F (EU1-16R) CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* GFCI / RCD 30MA Trip Inline length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 10MA Trip Versions .
* GFCI / RCD Plug Versions: 36025-RCD , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .
70140-RCD30
EUROPEAN SCHUKO PLUG, CEE 7/7 GFCI RCD, 16A-230V, TYPE E, F PLUG (EU1-16P), 50Hz, 30mA TRIP, IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.
70140-RCD10
EUROPEAN SCHUKO PLUG, 16A-230V (3680 WATTS), 50Hz, GFCI /RCD (PRCD-S) 10mA TRIP TYPE E, F PLUG, CEE 7/7 (EU1-16P), IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.
36025-RCD
EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 GFCI /RCD 30mA TRIP "DOWN ANGLE" (EU1-16P) TYPE E PLUG, TEST / RESET BUTTON, SCHUKO CEE 7/3 (EU1-16R) TYPE F CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* GFCI / RCD Plug extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 10MA Trip Versions .
* GFCI / RCD Inline Versions: 36025-RCDS10 , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .
70200x45
EUROPEAN (SCHUKO) GFCI (RCBO/RCD) OUTLET, 16A-250V, 50/60 Hz, 10mA TRIP, CEE 7/3 TYPE F (EU1-16R), SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, no reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
70225-10HGD
EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
71200x45
FRANCE, BELGIUM GFCI (RCBO/RCD) OUTLET, 16A-230V, 50/60 Hz, 10mA TRIP, CEE 7/5 TYPE E (FR1-16R), SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
71225
FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm. Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
72140-RCD
UK, BRITISH, UNITED KINGDOM PLUG, 13A-240V (GFCI /RCD) PRCD-S, 30mA TRIP, IP44 BS 1363A TYPE G PLUG (UK1-13P), FUSED 13 AMP., REWIREABLE ANGLE PLUG, BLACK.
Notes:
* GFCI/RCD plug requires "Reset" after a power failure. Not for use on life support medical equipment, refrigerators, freezers or other applications where power must be maintained.
37025-RCD
EXTENSION CORD, BRITISH, UK, UNITED KINGDOM GFCI (RCD) 13A-250V EXT. CORD, 30mA TRIP, BS 1363A 13 AMP. TYPE G PLUG (UK1-13P), BS 1363 TYPE G BRITISH, UK CONNECTOR (UK1-13R), POWER CORD 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* With integral hanger bracket.
* Extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT .
* GFCI / RCD Inline 10mA Versions: 37025-RCDS10 .
* GFCI / RCD Inline 30mA Versions: 37025-RCDS30 .
* Standard Extension Cords: 37025 .
37025-RCDS10
EXTENSION CORD, BRITISH, UK, UNITED KINGDOM IN-LINE GFCI (RCCB / RCD) PRCD-S EXT. CORD, 13A-250V, 10mA TRIP, BS 1363A 13 AMP. TYPE G PLUG (UK1-13P), BS 1363 TYPE G CONNECTOR (UK1-13R), POWER CORD 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* With integral hanger bracket.
* Extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT .
* GFCI / RCD Inline 30mA Versions: 37025-RCDS30 .
* GFCI / RCD Plug Versions: 37025-RCD .
* Standard Extension Cords: 37025 .
37025-RCDS30
EXTENSION CORD, BRITISH, UK, UNITED KINGDOM IN-LINE GFCI (RCCB / RCD) PRCD-S EXT. CORD, 13A-250V, 30mA TRIP, BS 1363A 13 AMP. TYPE G PLUG (UK1-13P), BS 1363 TYPE G CONNECTOR (UK1-13R), POWER CORD 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* With integral hanger bracket.
* Extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT .
* GFCI / RCD Inline 10mA Versions: 37025-RCDS10 .
* GFCI / RCD Plug Versions: 37025-RCD .
* Standard Extension Cords: 37025 .
72300-DS-10MA
BRITISH, UNITED KINGDOM 13 AMPERE-230 VOLT, 50Hz, GFCI [RCD] DUPLEX OUTLET, [UK1-13R], 10mA TRIP , BS 1363 TYPE G SOCKETS, SHUTTERED CONTACTS, (86mmX146mm)SIZE, PANEL MOUNT, WALL BOX MOUNT. WHITE.
Notes:
* Outlet mounts on European, British wall boxes with 120mm (120.6mm) centers.
* European wall boxes available # 72355X47D, 72355X35D, 72355X25D, 72355-F, 72365, 72365-RED.
* Passive design [automatic reset], will not trip on power failure.
* Weatherproof enclosure available # 74790-B2 [IP66 rated], Cover closes & locks over down angle plugs [Not all plug variations].
* Weatherproof cover available # 74790-DX [IP54 rated], weatherproofs outlets only [less mating plugs]. Contact sales for details.
* Not for use on life support, medical equipment, refrigeration equipment.
72300-WPD-10MA
BRITISH, UNITED KINGDOM 13A-250V WEATHERPROOF GFCI (RCD) DUPLEX OUTLET, 10mA TRIP , IP66 RATED (COVER CLOSED) (**) , 50Hz, BS 1363 (UK1-13R) TYPE G SOCKETS, SHUTTERED CONTACTS, IMPACT RESISTANT. GRAY.
Notes:
** Cover can be closed & locked over down angle plugs (not all angle plug variations).
* M20 knockout cable entries (top, bottom, sides), "Earth" grounding terminals.
* Passive design [automatic reset], will not trip on power failure.
* Not for use on life support, medical equipment, refrigeration equipment.
72300-S-10MA
BRITISH, UNITED KINGDOM 13 AMPERE-230 VOLT, 50Hz, GFCI (RCD) OUTLET, (UK1-13R), 10mA TRIP , BS 1363 TYPE G SOCKETS, SHUTTERED CONTACTS, PANEL MOUNT, WALL BOX MOUNT, (86mmX86mm SIZE), 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Passive design [automatic reset], will not trip on power failure.
* International wall boxes. Use # 72350X47D, # 72350X35D, # 72350-F, # 72360 series.
* Weatherproof enclosure available #74790-B1 (IP66 rated). Cover can be closed & locked over down angle plugs (not all angle plug variations).
* Not for use on life support, medical equipment, refrigeration equipment.
72300-WPS-10MA
BRITISH, UNITED KINGDOM 13A-250V WEATHERPROOF GFCI (RCD) OUTLET, 10mA TRIP , IP66 RATED (COVER CLOSED) (**) , 50Hz, BS 1363 (UK1-13R) TYPE G SOCKETS, SHUTTERED CONTACTS, IMPACT RESISTANT. GRAY.
Notes:
** Cover can be closed & locked over down angle plugs (not all angle plug variations).
* M20 knockout cable entries (top, bottom, sides), "Earth" grounding terminals.
* Enclosure UV stabilized PC, Temp. rating = -5°C to +40°C.
* Passive design [automatic reset], will not trip on power failure.
* Not for use on life support, medical equipment, refrigeration equipment.
72300-S-UV
UNIVERSAL INTERNATIONAL, EUROPEAN, BRITISH, AUSTRALIA, ASIA, THAILAND MULTI-CONFIGURATION 16 AMPERE-250 VOLT, 50-60Hz, GFCI (SRCD) OUTLET, 10mA TRIP, IP54 UNIVERSAL SOCKET, DOUBLE POLE TRIP, SHUTTERED CONTACTS, WALL BOX MOUNT OR PANEL MOUNT, (86mmX86mm SIZE), 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Passive design automatic reset, will not trip on power failure.
* Weatherproof enclosure available #74790-B1 (IP66 rated). Cover can be closed & locked over down angle plugs (not all angle plug variations).
* Not for use with #74790 and #74790-A
* European wall boxes available #72350X47D, 72350X35D, 72355X35DDG, 72350-F, 72360, 72360-RED.
* Not for use on life support, medical equipment, refrigeration equipment.
72325-D
BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD DUPLEX OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, GLAND TYPE CABLE ENTRY, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.
74140-RCD
AUSTRALIA / NEW ZEALAND PLUG, 10A-240V (GFCI /RCD) (AU1-10P), 30mA TRIP, REWIREABLE ANGLE PLUG, ACCEPTS 0.250-0.375" DIA. CORD. BLACK.
Notes:
* Plug connects with 10 Ampere, 15 Ampere, 20 Ampere Australian, New Zealand outlets, receptacles, connectors.
74200-NS
AUSTRALIAN / NEW ZEALAND 10 AMPERE 230-240 VOLT, 50Hz, GFCI/RCD, 10mA TRIP DUPLEX OUTLET (AU1-10R) AS/NZS 3112, SHUTTERED CONTACTS, ON/OFF SWITCHES, INDICATOR LIGHT, INTEGRAL WALL PLATE, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Mounts on American 2x4 wall boxes & International wall boxes with 39/32" (83mm / 84mm) mounting centers.
* Surface mounts on # 74225, # 84225-AR wall boxes or panel mount.
* GFCI/RCD allows for protection of downstream outlets.
* Not for use on life support, medical equipment, refrigeration equipment.
74335-10
AUSTRALIAN / NEW ZEALAND 10A-230V GFCI (RCBO/RCD) OUTLET (AU1-10R), 50/60 Hz, (10mA TRIP), IP55, SURFACE MOUNT. GRAY.
75525
ITALY, CHILE, SOUTH AMERICA 10A/16A-230V GFCI (RCBO/RCD) TYPE L DUPLEX OUTLET, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED ENCLOSURE, HORIZONTAL SURFACE MOUNT, GLAND TYPE CABLE ENTRY (**). GRAY.
Notes:
* Accepts Italy, Chile Type L 10 Ampere, 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets available.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
70200x45-IT
EUROPEAN (SCHUKO), ITALY, CHILE, S. AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, 50/60 Hz, 10mA TRIP, CEE 7/3 TYPE F (EU1-16R), TYPE L, (IT1-10R/IT2-16R), CEI 23-50 (S17) CEI 23-16, SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Accepts type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs, Euro CEE plugs, Italy, Chile type L 10 Ampere / 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
70225-10-IT
EUROPEAN SCHUKO, ITALY, CHILE, SOUTH AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, CEE 7/3 TYPE E, F, (EU1-16R), TYPE L, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts Type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs & Italy, Chile type L 10 Ampere & 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
76225x45
SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 Hz 10mA TRIP, FLUSH MOUNTS TO AMERICAN 2 GANG WALL BOXES. WHITE.
76225
SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
78225x45
DENMARK 13A-250V GFCI (RCBO/RCD) TYPE K OUTLET (DE1-13R), 50/60 Hz, 10mA TRIP. WHITE. FLUSH MOUNTS ON AMERICAN 2 GANG WALL BOXES.
78225
DENMARK 13A-230V GFCI (RCBO/RCD) TYPE K OUTLET, (DE1-13R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
73225x45
SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 TYPE M (UK1-15R, 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R , 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Flush mounts to American 2 gang 4x4 wall boxes.
73225
SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 / TYPE M (UK1-15R), 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E), IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY **), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts South Africa 25A-250V, 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
74725x45
CHINA 10 AMPERE-230 VOLT GFCI (RCBO/RCD), TYPE I (CH1-10R), 10mA TRIP, 50/60 Hz, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Flush mounts on American 4X4 wall box.
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74725
CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Protects Downstream outlets.
* No reset after power failure (Latched RCD).
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
85225x45
BRAZIL 10A-230V GFCI (RCBO/RCD) OUTLET, TYPE N, NBR 14136 (BR2-10R), 50/60 Hz 10mA TRIP. WHITE.
NOTES:
* Mounts on American 4X4 wall boxes.
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.
85225
BRAZIL 10A-230V GFCI (RCBO/RCD) OUTLET, NBR 14136 TYPE N (BR2-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
NOTES:
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.
77225x45
ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 10mA TRIP, 50/60 Hz, WHITE.
* Mounts on American 4X4 wall boxes.
77225
ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 10mA TRIP, 50/60 Hz, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
1597-I
15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. IVORY.
1597-W
15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. WHITE.
1597-BK
15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. BLACK.
2097-I
20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. IVORY.
2097-W
20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A , SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. WHITE.
2097-BK
20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. BLACK.
92105-WPV
AMERICAN GFCI OUTLET WEATHERPROOF COVER, VERTICAL MOUNT, GASKETED, GRAY.
Notes:
* Mounts on American 2x4 size wall boxes.
92105-WPH
AMERICAN GFCI OUTLET WEATHERPROOF COVER, HORIZONTAL MOUNT, GASKETED, GRAY.
Notes:
* Mounts on American 2x4 size wall boxes.
5266-GFCI
GFCI PLUG, 15A-120V VOLT 60Hz, NEMA 5-15P, 4-6mA TRIP, CLASS A, RAINPROOF, TEST / RESET BUTTONS, ON / OFF INDICATOR, ACCEPTS 18AWG-12AWG CONDUCTORS, CORD GRIP RANGE 0.358-0.480". BLACK.
Notes:
* Connects with NEMA 5-15R 15A-125V & NEMA 5-20R 20A-125V outlets.
5366-GFCI
GFCI PLUG, 20A-120V VOLT 60Hz, NEMA 5-20P, 4-6mA TRIP, CLASS A, RAINPROOF, TEST / RESET BUTTONS, ON / OFF INDICATOR, ACCEPTS 18AWG-12AWG CONDUCTORS, CORD GRIP RANGE 0.358-0.480". BLACK.
Notes:
* NEMA 5-15P (15A-120V) version available #5266-GFCI.
70400-UL
NORTH AMERICAN IN-LINE GFCI CONNECTOR, 20A-120V, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, MANUAL RESET, RAINPROOF. BLACK.
Notes:
* Requires “reset” after a power failure. Not for use on freezers, refrigerators, medical or other equipment where power must be maintained.
70400-ULAR
NORTH AMERICAN IN-LINE GFCI CONNECTOR, 15A-120V, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, AUTOMATIC RESET, RAINPROOF. BLACK.
Notes:
* No reset required after a power failure. Not for use on power tools, machines, equipment or other applications considered hazardous on automatic start up.
70140-RCD10
EUROPEAN SCHUKO PLUG, 16A-230V (3680 WATTS), 50Hz, GFCI /RCD (PRCD-S) 10mA TRIP TYPE E, F PLUG, CEE 7/7 (EU1-16P), IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.
70400-10MA
INTERNATIONAL IN-LINE GFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 10mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
70400-30MA
INTERNATIONAL IN-LINEGFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 30mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
74458x45
EUROPEAN GFCI / RCBO CIRCUIT BREAKER, (RCD / GFCI WITH OVER CURRENT PROTECTION), 16 AMPERE-230 VOLT, SINGLE POLE + NEUTRAL, 50/60 HZ, 10mA TRIP, 45mmX45mm MODULAR SIZE, TEST/BUTTON, INDICATOR LIGHT, WALL BOX, PANEL, DIN RAIL MOUNT. WHITE.
Notes:
* Mounts on American 2X4 wall boxes, requires frame # 79120X45-N & # 79130X45-N wall plate (White, Black, ALU, SS).
* Mounts on American 4X4 wall boxes, requires frame # 79210X45-N & # 79220X45-N wall plate (White, SS).
* Mounts on European (60mm on center) wall boxes, requires frame # 79250X45-N & wall plate # 79265X45-N.
* Panel mount frame # 79100X45. DIN rail mount Frame # 79595X45. Panel Mount Instruction Guide
* Surface mount boxes, Flush mount boxes, IP66 / IP55 Enclosures & GFCI / RCD European / International power outlets available.
* Complete range of modular devices and mounting component options. Modular Devices Link
236211
EUROPEAN / INTERNATIONAL GFCI RCBO 16 AMPERE-230 VOLT, COMBINED GFCI (RCD) & MCB (OVERLOAD) C-CURVE CIRCUIT BREAKER, 50HZ, 10mA TRIP, SINGLE POLE+NEUTRAL (1P+N) (2 MODULE SIZE), DIN RAIL MOUNT. GRAY.
236139
EUROPEAN / INTERNATIONAL GFCI RCBO 13 AMPERE-230 VOLT, COMBINED GFCI (RCD) & MCB (OVERLOAD) C-CURVE CIRCUIT BREAKER, 50HZ, 10mA TRIP, SINGLE POLE+NEUTRAL (1P+N) (2 MODULE SIZE), DIN RAIL MOUNT. GRAY.
236076
EUROPEAN / INTERNATIONAL GFCI RCBO 10 AMPERE-230 VOLT, COMBINED GFCI (RCD) & MCB (OVERLOAD) C-CURVE CIRCUIT BREAKER, 50HZ, 10mA TRIP, SINGLE POLE+NEUTRAL (1P+N) (2 MODULE SIZE), DIN RAIL MOUNT. GRAY.
007879
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 16A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 10mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.GRAY.
007886
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 16A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007887
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 20A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007888
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 25A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007889
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 32A-250V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007890
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 40A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
EAM162H
EUROPEAN / INTERNATIONAL 16A-230/240V "RCCB" (GFCI) CIRCUIT BREAKER, SINGLE POLE + NEUTRAL (2 MODULE SIZE), 30mA TRIP.
EAD02B
EUROPEAN / INTERNATIONAL SINGLE POLE 2A-230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD04B
EUROPEAN / INTERNATIONAL SINGLE POLE 4A-230/240V, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD06B
EUROPEAN / INTERNATIONAL SINGLE POLE 6 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD10B
EUROPEAN / INTERNATIONAL SINGLE POLE 10 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD13B
EUROPEAN / INTERNATIONAL SINGLE POLE 13 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD16B
EUROPEAN / INTERNATIONAL SINGLE POLE 16 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD20B
EUROPEAN / INTERNATIONAL SINGLE POLE 20 AMPERE 230/240 VOLT, 50Hz CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD25B
EUROPEAN / INTERNATIONAL SINGLE POLE 25 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD32B
EUROPEAN / INTERNATIONAL SINGLE POLE 32A-240V, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD40B
EUROPEAN / INTERNATIONAL SINGLE POLE 40 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD50B
EUROPEAN / INTERNATIONAL SINGLE POLE 50 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD63B
EUROPEAN / INTERNATIONAL SINGLE POLE 63 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
2CU16
EUROPEAN / INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 16A-415V (VDE), 480Y/277VAC, UL-CSA C CURVE, DIN RAIL MOUNT.
2CU32
INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 32A-480Y/277V AC UL-CSA, DIN RAIL MOUNT.
2CU40
INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 40A-480Y/277V AC UL-CSA, DIN RAIL MOUNT.
2CU63
INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 63A-480Y/277VAC UL-CSA, DIN RAIL MOUNT.
3CU16
EUROPEAN / INTERNATIONAL CIRCUIT BREAKER, TRIPLE POLE, 16 AMPERE-415 VOLT VDE, 480Y/277VAC UL-CSA DIN RAIL MOUNT.
3CU32
INTERNATIONAL CIRCUIT BREAKER, TRIPLE POLE, 32A-480Y/277 V (AC) (UL-CSA), DIN RAIL MOUNT.
3CU63
INTERNATIONAL CIRCUIT BREAKER, TRIPLE POLE, 63A-480Y/277V (AC), DIN RAIL MOUNT.
70400-10MA
INTERNATIONAL IN-LINE GFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 10mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
70400-30MA
INTERNATIONAL IN-LINEGFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 30mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
83100
UK, BRITISH, UNITED KINGDOM, SAUDI ARABIA, GULF STATES, 13A-250V POWER SUPPLY CORD, BS 1363A TYPE G, UK1-13P, UK, BRITISH UNITED KINGDOM PLUG, 13 AMP. BS 1362 FUSE, STRIPPED ENDS, 2.5 METERS [8FT-2IN] [98"] LONG. BLACK.
Length: 2.5 METERS [8FT-2IN]
82070
AUSTRALIA / NEW ZEALAND 15 AMPERE-250 VOLT POWER SUPPLY CORD, AS/NZS 4417 [RCM] / AS/NZS 3112 PLUG, TYPE I [AU2-15P], GTSA-3 1.5mm2 CORD, 2 POLE-3 WIRE GROUNDING [2P+E], STRIPPED ENDS, 2.5 METERS [8FT-2IN] [98"] LONG. BLACK.
Length: 2.5 METERS [8FT-2IN]
81070
EUROPEAN CEE 7/7 SCHUKO 16A-250V POWER SUPPLY CORD, [EU1-16P] TYPE E, F PLUG, STRIPPED ENDS, 2.5 METERS [8FT-2IN] [98"] LONG. BLACK.
Length: 2.5 METERS [8FT-2IN]
36025-RCDS10
EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 (EU1-16P) TYPE E PLUG WITH IN-LINE GFCI /RCD, 10mA TRIP, TEST/RESET BUTTON, SCHUKO CEE 7/3 (EU1-16R) TYPE F CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* GFCI / RCD 10MA Trip Inline length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 30MA Trip Versions .
* GFCI / RCD Plug Versions: 36025-RCD , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .
36025-RCDS30
EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 TYPE E (EU1-16P) PLUG WITH "IN-LINE" GFCI /RCD, 30mA TRIP, TEST/RESET BUTTON, SCHUKO CEE 7/3 TYPE F (EU1-16R) CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* GFCI / RCD 30MA Trip Inline length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 10MA Trip Versions .
* GFCI / RCD Plug Versions: 36025-RCD , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .
70140-RCD30
EUROPEAN SCHUKO PLUG, CEE 7/7 GFCI RCD, 16A-230V, TYPE E, F PLUG (EU1-16P), 50Hz, 30mA TRIP, IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.
70140-RCD10
EUROPEAN SCHUKO PLUG, 16A-230V (3680 WATTS), 50Hz, GFCI /RCD (PRCD-S) 10mA TRIP TYPE E, F PLUG, CEE 7/7 (EU1-16P), IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.
36025-RCD
EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 GFCI /RCD 30mA TRIP "DOWN ANGLE" (EU1-16P) TYPE E PLUG, TEST / RESET BUTTON, SCHUKO CEE 7/3 (EU1-16R) TYPE F CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* GFCI / RCD Plug extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 10MA Trip Versions .
* GFCI / RCD Inline Versions: 36025-RCDS10 , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .
70200x45
EUROPEAN (SCHUKO) GFCI (RCBO/RCD) OUTLET, 16A-250V, 50/60 Hz, 10mA TRIP, CEE 7/3 TYPE F (EU1-16R), SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, no reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
70225-10HGD
EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) DUPLEX OUTLET, TYPE F (EU1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
71200x45
FRANCE, BELGIUM GFCI (RCBO/RCD) OUTLET, 16A-230V, 50/60 Hz, 10mA TRIP, CEE 7/5 TYPE E (FR1-16R), SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
71225
FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm. Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
72140-RCD
UK, BRITISH, UNITED KINGDOM PLUG, 13A-240V (GFCI /RCD) PRCD-S, 30mA TRIP, IP44 BS 1363A TYPE G PLUG (UK1-13P), FUSED 13 AMP., REWIREABLE ANGLE PLUG, BLACK.
Notes:
* GFCI/RCD plug requires "Reset" after a power failure. Not for use on life support medical equipment, refrigerators, freezers or other applications where power must be maintained.
37025-RCD
EXTENSION CORD, BRITISH, UK, UNITED KINGDOM GFCI (RCD) 13A-250V EXT. CORD, 30mA TRIP, BS 1363A 13 AMP. TYPE G PLUG (UK1-13P), BS 1363 TYPE G BRITISH, UK CONNECTOR (UK1-13R), POWER CORD 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* With integral hanger bracket.
* Extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT .
* GFCI / RCD Inline 10mA Versions: 37025-RCDS10 .
* GFCI / RCD Inline 30mA Versions: 37025-RCDS30 .
* Standard Extension Cords: 37025 .
37025-RCDS10
EXTENSION CORD, BRITISH, UK, UNITED KINGDOM IN-LINE GFCI (RCCB / RCD) PRCD-S EXT. CORD, 13A-250V, 10mA TRIP, BS 1363A 13 AMP. TYPE G PLUG (UK1-13P), BS 1363 TYPE G CONNECTOR (UK1-13R), POWER CORD 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* With integral hanger bracket.
* Extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT .
* GFCI / RCD Inline 30mA Versions: 37025-RCDS30 .
* GFCI / RCD Plug Versions: 37025-RCD .
* Standard Extension Cords: 37025 .
37025-RCDS30
EXTENSION CORD, BRITISH, UK, UNITED KINGDOM IN-LINE GFCI (RCCB / RCD) PRCD-S EXT. CORD, 13A-250V, 30mA TRIP, BS 1363A 13 AMP. TYPE G PLUG (UK1-13P), BS 1363 TYPE G CONNECTOR (UK1-13R), POWER CORD 7.6 METERS (25 FEET) (300") LONG. BLACK.
Length: 7.6 METERS (25 FEET)
Notes:
* With integral hanger bracket.
* Extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT .
* GFCI / RCD Inline 10mA Versions: 37025-RCDS10 .
* GFCI / RCD Plug Versions: 37025-RCD .
* Standard Extension Cords: 37025 .
72300-DS-10MA
BRITISH, UNITED KINGDOM 13 AMPERE-230 VOLT, 50Hz, GFCI [RCD] DUPLEX OUTLET, [UK1-13R], 10mA TRIP , BS 1363 TYPE G SOCKETS, SHUTTERED CONTACTS, (86mmX146mm)SIZE, PANEL MOUNT, WALL BOX MOUNT. WHITE.
Notes:
* Outlet mounts on European, British wall boxes with 120mm (120.6mm) centers.
* European wall boxes available # 72355X47D, 72355X35D, 72355X25D, 72355-F, 72365, 72365-RED.
* Passive design [automatic reset], will not trip on power failure.
* Weatherproof enclosure available # 74790-B2 [IP66 rated], Cover closes & locks over down angle plugs [Not all plug variations].
* Weatherproof cover available # 74790-DX [IP54 rated], weatherproofs outlets only [less mating plugs]. Contact sales for details.
* Not for use on life support, medical equipment, refrigeration equipment.
72300-WPD-10MA
BRITISH, UNITED KINGDOM 13A-250V WEATHERPROOF GFCI (RCD) DUPLEX OUTLET, 10mA TRIP , IP66 RATED (COVER CLOSED) (**) , 50Hz, BS 1363 (UK1-13R) TYPE G SOCKETS, SHUTTERED CONTACTS, IMPACT RESISTANT. GRAY.
Notes:
** Cover can be closed & locked over down angle plugs (not all angle plug variations).
* M20 knockout cable entries (top, bottom, sides), "Earth" grounding terminals.
* Passive design [automatic reset], will not trip on power failure.
* Not for use on life support, medical equipment, refrigeration equipment.
72300-S-10MA
BRITISH, UNITED KINGDOM 13 AMPERE-230 VOLT, 50Hz, GFCI (RCD) OUTLET, (UK1-13R), 10mA TRIP , BS 1363 TYPE G SOCKETS, SHUTTERED CONTACTS, PANEL MOUNT, WALL BOX MOUNT, (86mmX86mm SIZE), 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Passive design [automatic reset], will not trip on power failure.
* International wall boxes. Use # 72350X47D, # 72350X35D, # 72350-F, # 72360 series.
* Weatherproof enclosure available #74790-B1 (IP66 rated). Cover can be closed & locked over down angle plugs (not all angle plug variations).
* Not for use on life support, medical equipment, refrigeration equipment.
72300-WPS-10MA
BRITISH, UNITED KINGDOM 13A-250V WEATHERPROOF GFCI (RCD) OUTLET, 10mA TRIP , IP66 RATED (COVER CLOSED) (**) , 50Hz, BS 1363 (UK1-13R) TYPE G SOCKETS, SHUTTERED CONTACTS, IMPACT RESISTANT. GRAY.
Notes:
** Cover can be closed & locked over down angle plugs (not all angle plug variations).
* M20 knockout cable entries (top, bottom, sides), "Earth" grounding terminals.
* Enclosure UV stabilized PC, Temp. rating = -5°C to +40°C.
* Passive design [automatic reset], will not trip on power failure.
* Not for use on life support, medical equipment, refrigeration equipment.
72300-S-UV
UNIVERSAL INTERNATIONAL, EUROPEAN, BRITISH, AUSTRALIA, ASIA, THAILAND MULTI-CONFIGURATION 16 AMPERE-250 VOLT, 50-60Hz, GFCI (SRCD) OUTLET, 10mA TRIP, IP54 UNIVERSAL SOCKET, DOUBLE POLE TRIP, SHUTTERED CONTACTS, WALL BOX MOUNT OR PANEL MOUNT, (86mmX86mm SIZE), 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Passive design automatic reset, will not trip on power failure.
* Weatherproof enclosure available #74790-B1 (IP66 rated). Cover can be closed & locked over down angle plugs (not all angle plug variations).
* Not for use with #74790 and #74790-A
* European wall boxes available #72350X47D, 72350X35D, 72355X35DDG, 72350-F, 72360, 72360-RED.
* Not for use on life support, medical equipment, refrigeration equipment.
72325-D
BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD DUPLEX OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, GLAND TYPE CABLE ENTRY, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.
74140-RCD
AUSTRALIA / NEW ZEALAND PLUG, 10A-240V (GFCI /RCD) (AU1-10P), 30mA TRIP, REWIREABLE ANGLE PLUG, ACCEPTS 0.250-0.375" DIA. CORD. BLACK.
Notes:
* Plug connects with 10 Ampere, 15 Ampere, 20 Ampere Australian, New Zealand outlets, receptacles, connectors.
74200-NS
AUSTRALIAN / NEW ZEALAND 10 AMPERE 230-240 VOLT, 50Hz, GFCI/RCD, 10mA TRIP DUPLEX OUTLET (AU1-10R) AS/NZS 3112, SHUTTERED CONTACTS, ON/OFF SWITCHES, INDICATOR LIGHT, INTEGRAL WALL PLATE, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Mounts on American 2x4 wall boxes & International wall boxes with 39/32" (83mm / 84mm) mounting centers.
* Surface mounts on # 74225, # 84225-AR wall boxes or panel mount.
* GFCI/RCD allows for protection of downstream outlets.
* Not for use on life support, medical equipment, refrigeration equipment.
74335-10
AUSTRALIAN / NEW ZEALAND 10A-230V GFCI (RCBO/RCD) OUTLET (AU1-10R), 50/60 Hz, (10mA TRIP), IP55, SURFACE MOUNT. GRAY.
75525
ITALY, CHILE, SOUTH AMERICA 10A/16A-230V GFCI (RCBO/RCD) TYPE L DUPLEX OUTLET, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED ENCLOSURE, HORIZONTAL SURFACE MOUNT, GLAND TYPE CABLE ENTRY (**). GRAY.
Notes:
* Accepts Italy, Chile Type L 10 Ampere, 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets available.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
70200x45-IT
EUROPEAN (SCHUKO), ITALY, CHILE, S. AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, 50/60 Hz, 10mA TRIP, CEE 7/3 TYPE F (EU1-16R), TYPE L, (IT1-10R/IT2-16R), CEI 23-50 (S17) CEI 23-16, SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Accepts type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs, Euro CEE plugs, Italy, Chile type L 10 Ampere / 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
70225-10-IT
EUROPEAN SCHUKO, ITALY, CHILE, SOUTH AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, CEE 7/3 TYPE E, F, (EU1-16R), TYPE L, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts Type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs & Italy, Chile type L 10 Ampere & 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.
76225x45
SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 Hz 10mA TRIP, FLUSH MOUNTS TO AMERICAN 2 GANG WALL BOXES. WHITE.
76225
SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
78225x45
DENMARK 13A-250V GFCI (RCBO/RCD) TYPE K OUTLET (DE1-13R), 50/60 Hz, 10mA TRIP. WHITE. FLUSH MOUNTS ON AMERICAN 2 GANG WALL BOXES.
78225
DENMARK 13A-230V GFCI (RCBO/RCD) TYPE K OUTLET, (DE1-13R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
73225x45
SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 TYPE M (UK1-15R, 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R , 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Flush mounts to American 2 gang 4x4 wall boxes.
73225
SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 / TYPE M (UK1-15R), 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E), IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY **), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts South Africa 25A-250V, 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
74725x45
CHINA 10 AMPERE-230 VOLT GFCI (RCBO/RCD), TYPE I (CH1-10R), 10mA TRIP, 50/60 Hz, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Flush mounts on American 4X4 wall box.
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74725
CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Protects Downstream outlets.
* No reset after power failure (Latched RCD).
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
85225x45
BRAZIL 10A-230V GFCI (RCBO/RCD) OUTLET, TYPE N, NBR 14136 (BR2-10R), 50/60 Hz 10mA TRIP. WHITE.
NOTES:
* Mounts on American 4X4 wall boxes.
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.
85225
BRAZIL 10A-230V GFCI (RCBO/RCD) OUTLET, NBR 14136 TYPE N (BR2-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
NOTES:
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.
77225x45
ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 10mA TRIP, 50/60 Hz, WHITE.
* Mounts on American 4X4 wall boxes.
77225
ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 10mA TRIP, 50/60 Hz, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
1597-I
15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. IVORY.
1597-W
15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. WHITE.
1597-BK
15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. BLACK.
2097-I
20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. IVORY.
2097-W
20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A , SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. WHITE.
2097-BK
20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. BLACK.
92105-WPV
AMERICAN GFCI OUTLET WEATHERPROOF COVER, VERTICAL MOUNT, GASKETED, GRAY.
Notes:
* Mounts on American 2x4 size wall boxes.
92105-WPH
AMERICAN GFCI OUTLET WEATHERPROOF COVER, HORIZONTAL MOUNT, GASKETED, GRAY.
Notes:
* Mounts on American 2x4 size wall boxes.
5266-GFCI
GFCI PLUG, 15A-120V VOLT 60Hz, NEMA 5-15P, 4-6mA TRIP, CLASS A, RAINPROOF, TEST / RESET BUTTONS, ON / OFF INDICATOR, ACCEPTS 18AWG-12AWG CONDUCTORS, CORD GRIP RANGE 0.358-0.480". BLACK.
Notes:
* Connects with NEMA 5-15R 15A-125V & NEMA 5-20R 20A-125V outlets.
5366-GFCI
GFCI PLUG, 20A-120V VOLT 60Hz, NEMA 5-20P, 4-6mA TRIP, CLASS A, RAINPROOF, TEST / RESET BUTTONS, ON / OFF INDICATOR, ACCEPTS 18AWG-12AWG CONDUCTORS, CORD GRIP RANGE 0.358-0.480". BLACK.
Notes:
* NEMA 5-15P (15A-120V) version available #5266-GFCI.
70400-UL
NORTH AMERICAN IN-LINE GFCI CONNECTOR, 20A-120V, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, MANUAL RESET, RAINPROOF. BLACK.
Notes:
* Requires “reset” after a power failure. Not for use on freezers, refrigerators, medical or other equipment where power must be maintained.
70400-ULAR
NORTH AMERICAN IN-LINE GFCI CONNECTOR, 15A-120V, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, AUTOMATIC RESET, RAINPROOF. BLACK.
Notes:
* No reset required after a power failure. Not for use on power tools, machines, equipment or other applications considered hazardous on automatic start up.
70140-RCD10
EUROPEAN SCHUKO PLUG, 16A-230V (3680 WATTS), 50Hz, GFCI /RCD (PRCD-S) 10mA TRIP TYPE E, F PLUG, CEE 7/7 (EU1-16P), IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.
70400-10MA
INTERNATIONAL IN-LINE GFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 10mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
70400-30MA
INTERNATIONAL IN-LINEGFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 30mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.
74458x45
EUROPEAN GFCI / RCBO CIRCUIT BREAKER, (RCD / GFCI WITH OVER CURRENT PROTECTION), 16 AMPERE-230 VOLT, SINGLE POLE + NEUTRAL, 50/60 HZ, 10mA TRIP, 45mmX45mm MODULAR SIZE, TEST/BUTTON, INDICATOR LIGHT, WALL BOX, PANEL, DIN RAIL MOUNT. WHITE.
Notes:
* Mounts on American 2X4 wall boxes, requires frame # 79120X45-N & # 79130X45-N wall plate (White, Black, ALU, SS).
* Mounts on American 4X4 wall boxes, requires frame # 79210X45-N & # 79220X45-N wall plate (White, SS).
* Mounts on European (60mm on center) wall boxes, requires frame # 79250X45-N & wall plate # 79265X45-N.
* Panel mount frame # 79100X45. DIN rail mount Frame # 79595X45. Panel Mount Instruction Guide
* Surface mount boxes, Flush mount boxes, IP66 / IP55 Enclosures & GFCI / RCD European / International power outlets available.
* Complete range of modular devices and mounting component options. Modular Devices Link
236211
EUROPEAN / INTERNATIONAL GFCI RCBO 16 AMPERE-230 VOLT, COMBINED GFCI (RCD) & MCB (OVERLOAD) C-CURVE CIRCUIT BREAKER, 50HZ, 10mA TRIP, SINGLE POLE+NEUTRAL (1P+N) (2 MODULE SIZE), DIN RAIL MOUNT. GRAY.
236139
EUROPEAN / INTERNATIONAL GFCI RCBO 13 AMPERE-230 VOLT, COMBINED GFCI (RCD) & MCB (OVERLOAD) C-CURVE CIRCUIT BREAKER, 50HZ, 10mA TRIP, SINGLE POLE+NEUTRAL (1P+N) (2 MODULE SIZE), DIN RAIL MOUNT. GRAY.
236076
EUROPEAN / INTERNATIONAL GFCI RCBO 10 AMPERE-230 VOLT, COMBINED GFCI (RCD) & MCB (OVERLOAD) C-CURVE CIRCUIT BREAKER, 50HZ, 10mA TRIP, SINGLE POLE+NEUTRAL (1P+N) (2 MODULE SIZE), DIN RAIL MOUNT. GRAY.
007879
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 16A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 10mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.GRAY.
007886
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 16A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007887
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 20A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007888
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 25A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007889
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 32A-250V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
007890
EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 40A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 30mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.
EAM162H
EUROPEAN / INTERNATIONAL 16A-230/240V "RCCB" (GFCI) CIRCUIT BREAKER, SINGLE POLE + NEUTRAL (2 MODULE SIZE), 30mA TRIP.
EAD02B
EUROPEAN / INTERNATIONAL SINGLE POLE 2A-230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD04B
EUROPEAN / INTERNATIONAL SINGLE POLE 4A-230/240V, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD06B
EUROPEAN / INTERNATIONAL SINGLE POLE 6 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD10B
EUROPEAN / INTERNATIONAL SINGLE POLE 10 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD13B
EUROPEAN / INTERNATIONAL SINGLE POLE 13 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD16B
EUROPEAN / INTERNATIONAL SINGLE POLE 16 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD20B
EUROPEAN / INTERNATIONAL SINGLE POLE 20 AMPERE 230/240 VOLT, 50Hz CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD25B
EUROPEAN / INTERNATIONAL SINGLE POLE 25 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD32B
EUROPEAN / INTERNATIONAL SINGLE POLE 32A-240V, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD40B
EUROPEAN / INTERNATIONAL SINGLE POLE 40 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD50B
EUROPEAN / INTERNATIONAL SINGLE POLE 50 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
EAD63B
EUROPEAN / INTERNATIONAL SINGLE POLE 63 AMPERE 230/240 VOLT, 50Hz, CIRCUIT BREAKER, IP20 RATED, DIN RAIL MOUNT.
2CU16
EUROPEAN / INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 16A-415V (VDE), 480Y/277VAC, UL-CSA C CURVE, DIN RAIL MOUNT.
2CU32
INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 32A-480Y/277V AC UL-CSA, DIN RAIL MOUNT.
2CU40
INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 40A-480Y/277V AC UL-CSA, DIN RAIL MOUNT.
2CU63
INTERNATIONAL CIRCUIT BREAKER, DOUBLE POLE, 63A-480Y/277VAC UL-CSA, DIN RAIL MOUNT.
3CU16
EUROPEAN / INTERNATIONAL CIRCUIT BREAKER, TRIPLE POLE, 16 AMPERE-415 VOLT VDE, 480Y/277VAC UL-CSA DIN RAIL MOUNT.
3CU32
INTERNATIONAL CIRCUIT BREAKER, TRIPLE POLE, 32A-480Y/277 V (AC) (UL-CSA), DIN RAIL MOUNT.
3CU63
INTERNATIONAL CIRCUIT BREAKER, TRIPLE POLE, 63A-480Y/277V (AC), DIN RAIL MOUNT.